Home > Exhibition > Content

Bioreactor makes perfusion culture easier

Jul 22, 2019

Bioreactor makes perfusion culture easier


WAVE Bioreactor Systems - Cell culture procedures Summary
Several protocols have been developed for cultivating various cell types in the WAVE Bioreactor™ system. These are provided as a useful starting point for your own experiments. Cultivation of: cells on Hillex microcarriers using WAVE Bioreactor Systems 2/10 and 20/50 cells on Cultispher microcarriers using WAVE Bioreactor Systems 2/10 and 20/50 cells on Cytodex 3 microcarriers using WAVE Bioreactor Systems 2/10 and 20/50 cells on Fibra-Cel carriers using WAVE Bioreactor Systems 2/10 and 20/50 CHO cells in suspension using WAVE Bioreactor Systems 2/10 and 20/50 CHO cells in suspension using WAVE Bioreactor System 200 HEK 293 cells in suspension using WAVE Bioreactor Systems 2/10 and 20/50 HEK 293 cells in suspension using WAVE Bioreactor System 200 hybridoma cells in suspension using WAVE Bioreactor Systems 2/10 and 20/50 hybridoma cells in suspension using WAVE Bioreactor System 200 NS0 cells in suspension using WAVE Bioreactor Systems 2/10 and 20/50 NS0 cells in suspension using WAVE Bioreactor System 200 T cells in suspension using WAVE Bioreactor Systems 2/10 and 20/50 E. coli bacteria using WAVE Bioreactor Systems 2/10 and 20/50 E. coli bacteria using WAVE Bioreactor System 200 BTI-TN-5B1-4 insect cells in suspension using WAVE Bioreactor Systems 2/10 and 20/50 BTI-TN-5B1-4 insect cells in suspension using WAVE Bioreactor System 200 Sf9 and Sf21 insect cells in suspension using WAVE Bioreactor Systems 2/10 and 20/50 Sf9 and Sf21 insect cells in suspension using WAVE Bioreactor System 200 plant cells in suspension using WAVE Bioreactor Systems 2/10 and 20/50 yeast cells using WAVE Bioreactor Systems 2/10 and 20/50 yeast cells using WAVE Bioreactor System 200 And: Cellbag disposable bioreactor pretreatment for the use of chemically defined lipid supplements Perfusion cell culture using WAVE Bioreactor Systems 2/10 and 20/50 Cultivation of CHO and HEK293 cells in PEI transfection reagent using WAVE Bioreactor Systems 2/10 and 20/50 “The use of branched or linear PEI for transfection purposes is covered by existing intellectual property rights, including U.S. Patent 6,013,240, European Patent 0770140 and foreign equivalents, for which Polyplus-transfection™ is the worldwide exclusive licensee. A license must be obtained from Polyplus-transfection™ if PEI is used for the transfection of cells”.Close

Brochure

250-liters-lee-industries-fermenter-bioreactor


Cell technologies. Your vision. Our expertise. Imagine the possibilities Summary
An overview of our products for drug discovery and cell therapy applications from high-content imaging and analysis using IN Cell Analyzer, through cell separation using Ficoll-Paque PREMIUM and expansion using WAVE Bioreactor, to automated cell processing on Celution, StemSource, AXP AutoXpress, and Res-Q 60 BMC.systems. A range of customized services (Cell Factory) to meet the particular needs of large-scale cell production and efficient assay development are also described.Close


Instrument Services for WAVE Bioreactor Systems Summary
WAVE technology has been at the forefront of single-use technologies for the processing of biopharmaceuticals. WAVE Bioreactors require no cleaning or sterilization, providing ease of operation and protection against cross contamination. WAVE Bioreactor systems maximize uptime, efficiency, and productivity, giving you peace of mind.Close


Plug & Play, ReadyToProcess™, Ready-to-use technologies for greater speed and agility in bioprocessing Summary
Biopharmaceutical development and manufacturing demands scalable processes that can be quickly developed, easily implemented, and smoothly transferred to production. Ready-to-use technologies play a crucial role in providing the flexibility to support multiproduct facilities. They deliver process time savings by removing steps such as cleaning and cleaning validation, and thus allow for faster changeover between products.Close


250-liters-lee-industries-fermenter-bioreactor-57012


Data File


WAVE Bioreactor™ Systems 2/10 and 20/50 Summary
The WAVE Bioreactor 2/10 and 20/50 systems are part of ReadyToProcess platform of ready-to-use products. The system is a cell culture instrument for the production of recombinant proteins in mammalian and insect cell lines in batch, fed-batch, and perfusion culture. Culture medium and cells are loaded into the Cellbag™ bioreactor, which is a single-use, presterilized bag. The Cellbag bioreactor is placed on a rocking base. The rocking motion induces waves in the cell culture fluid within the Cellbag bioreactor to provide efficient mixing and gas transfer. The resulting environment within the Cellbag bioreactor can easily support 1 × 107 cells/mL. The Cellbag bioreactor requires no cleaning or sterilization, providing easy operation and protection against cross contamination. As part of ReadyToProcess platform, WAVE Bioreactor brings flexibility and speed to upstream processing of biologicals. ReadyToProcess platform comprises WAVE Bioreactor systems, WAVE Mixer™, tubing sealers and fusers, hollow fiber and normal flow filters, prepacked chromatography columns, and ÄKTA™ ready chromatography system with a disposable flow path, as well as the assemblies and connections in between. The platform is scalable from the lab bench to manufacturing.Close


WAVE systems (small) PM Fact Sheet


Instruction/Protocol



Addendum Installation of WAVE Bioreactor 2/10 system Summary
This addendum describes the following changes made to the WAVE Bioreactor 2/10.Close


Perfusion Module PERFCONT2E Summary
This addendum to WAVE Bioreactor™ 2/10 Operator Manual (87-4500-23 edition AH) describes the upgraded Perfusion Module PERFCONT2E. Perfusion culture is enabled if an external instrument module for perfusion cultivation, PERFCONT2E, is installed. Periodically during perfusion, feed (culture media) is added and cell-free culture media removed. This may increase the cell concentration and viability. The PERFCONT2E perfusion module consists of a digital weighing scale and peristaltic feed and harvest pumps. The unit is designed for use with GE Healthcare patented perfusion cell culture bags. These bags have an internal filter that only allows cell-free harvest to be removed without the need for any external recycle loop or device.Close


250-liters-lee-industries-fermenter-bioreactor-57015



User Manual



Stand-alone instruments for WAVE Bioreactor™ 2/10 and 20/50 Operating instructions Summary
This manual provide you with the instructions needed to handle WAVE Bioreactor system optional stand-alone instruments. For further information regarding the use of WAVE Bioreactor 2/10, WAVE Bioreactor 20/50 and WAVEPOD™ II1, refer to WAVE Bioreactor System BASE 2/10 EH Operating Instructions and WAVE Bioreactor 20/50 and WAVEPOD II User Manual, respectively.Close


WAVE Bioreactor 2/10 - Operator Manual Summary
All users must read this entire manual to fully understand the safe use of WAVE Bioreactor™ 2/10.Close


WAVE Bioreactor Supervisory control and data aquisition software - PCDAQ/SCADA Manual


WAVE Bioreactor™ 2/10 and 20/50 systems Operating Instructions - Original instructions Summary
The Operating Instructions provide you with the instructions needed to handle WAVE Bioreactor™ 2/10 and 20/50 systems in a safe way.